We use state-of-the-art distributed data loggers with high precision sensors to monitor full stadium grandstands or the sway of tall buildings.
These provide identification of key dynamic properties, including natural frequencies and amplitude of vibrations to verify a code-compliant structure.
Full Scale Dynamics also utilise multiple near-noiseless actuators for “forced” vibration testing on floors, staircases and footbridges. These enable efficient monitoring of large areas with high accuracy.
Initial results can often be provided on-site, providing quality assurance and confidence